化學(xué)分析儀

簡要描述:1)可作免疫化學(xué)測定,配其他配件可測Na , K , Cl-, Li 等元素;2)每天可處理300個樣品;

  • 產(chǎn)品型號:ANALETTE型
  • 廠商性質(zhì):經(jīng)銷商
  • 更新時間:2023-08-16
  • 瀏覽次數(shù):3637

產(chǎn)品介紹

進口analette型化學(xué)分析儀

 

features

processing speeds up to 300 tests per hour

integrated reporting with full demographics

integrated wand bar-code scheduling and patient identification.

24-hour, 7 day per week standby electrolyte capability

automatic daily maintenance

system principle

 

random access, bench-top open system with 24 wavelengths available for applications. incorporates a concave holographic grating/diode array spectrophotometer with a spectral response from 340-740 nm. wavelengths of 340, 380, 405, 440, 465, 475, 490, 500, 512, 525, 540, 550, 560, 575, 585, 600, 610, 630, 640, 650, 675, 685, 700, 740 nm are standard. control of sample and reagent handing, assay and data processing is fully automatic through an ibm compatible 486 computer with keyboard and fourteen inch color display. tests are processed at a rate of over 140 tests per hour with workload throughput rate of about 130 tests using synermed reagents and applications. the system is open for the addition of tests which may be added through parameter settings entered through the keyboard.

 

reagent storage

reagents for up to 24 methods can be stored "on-board". over 100 additional methods can be pre-programmed and se-lected through bar code or keyboard.

sample presentation

there are four options for sample presentation:

sample tray for 42 disposable cups

sample tray for 42 seventy-five mm primary collection tubes

sample tray for 72 micro cups

stat samples can be added at any time

patient identification and workload scheduling

pre-printed barcode labels for sample tubes may be used or ma be generated through an optional printer using an optional utility installed on the system

duplicate barcode labels or sequential numbers may be used to label sample tube and requsistion.

each speciman may be identified by barcode wand reader or its number may be entered through the keyboard

test se-lection by patient sample can be achieved by wand reading a barcoded test se-lection sheet. profiles may be se-lected in the same way. alternatively, the keyboard can be used with a test se-lection utility.

fully documented final reports including test results, normal limits, patient name, physician, and identification number are printed in a format which can be se-lected and modified by the user.

extensive archiving of results is provided using the system"s hard disk.

on-line quality control

graphing of results, trends, and levy-jennings plots using 60 day fifo (first in first out)method, are standard.

assoy modes

assay modes for end point, zero order kinetic, first order kinetic, and ummunochemical reactions are provided. reagent volumes of as little as 180 µl and as high as 350 µl may be detected. sample volumes from 2-150 µl may be se-lected.

calibration

up to five calibrators may be used for immunochemical reactions. factor colibration may also be used. calibrator values and lot numbers are stored in system memory.

automatic pre-dilution for immunoassay

immunochemistry methods requiring pre-dilution of the sample are performed directly on serum by the automatic performance of a pre-dilution. the pre-dilution can be set for each method in the test porometers menu for each method. thus, each method can have a unique pre-dilution.

built-in diagnostics

the system monitors a variety of instruument operations and system performance can be monitored through the keyboard.

reagent level sensing is automatic.

serum level sensing is automatic.

walk-away operation

the system has a cuvette capacity of 140 cuvettes which are loaded as 10 cuvette segments. this provides for unattended operation of more than one hour.

immunochemistry capability

immunoproteins, therapeutic drugs, drigs of abuse and hormones can be assayed with the system.

curve-fitting math for up to five standards is integral.

automatic pre-dilution by method.

180 µl miniimum read volume provides economy for immunochemistry reagent use.

small volume reagent storage is provided.

disposable cuvette avoids troublesome and expensive cross contamiination and consequent repeats or errors.

system integration

the addition of the pluslyte with autosampler enables processinf electrolytes with integrated sample management and report generation for na , k , cl-, li and bicarbonate.

the analette offers value

highest testing rate per instrument cost.

flexibility - random, stat, batch, special chemistry, immunochemistry, routine assay and profile.

simplicity - computer familiarity is unnecessary. limited keyboard interaction is required.

economy - 180 µl minimum reagent volume.

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

聯(lián)


久久爱国产视频在线| 在线丝袜美腿| 国产真人一级| 有限公司招聘| 国产黄A三级三级三级AV | 美性台湾佬中文网22www| 双击以获取CaoPorn的视频地址 | 久久青青草原精品老司机| 热国产精品丝袜| 美女护士久久| 国产精品69久久久久久久 | 免费诱惑背后的色情帝国| www日本高清视频官方版| 《老鸭窝免费视频》剧情片手机免费播放| 麻豆国产视频| av女优中文字幕电影| 精品国产丝袜在线拍国语| 别让爱你的人等太久| 黄色大片》日韩电影手机免费播放| 色老大综合官方版| 性感欧美女神遭偷拍| 台湾佬在线视频下载免费版| 最新在线防屏蔽国产一区| 四虎影永久免费在线观看一区官方网站| 国产亚洲欧洲AV综合一区| 免费污污网站| www.日本欧美日韩亚洲| 玖玖热在线精品视频99| 日本不卡一区二区免费 | 免费草逼视频官方版| 爰片久久毛片美女图片| 《艹比视频》视频大全手机免费观看| 让春心在午夜里激情荡漾4| 热门日韩台湾good电影| 《欧美性精品人妖| 99re这里只有精品国产精品| 《good在线观看播放》免费观看超清| 成人免费亚洲电影| 双击以获取CaoPorn的视频地址| 国产精品成人一区二区三区| 精品这里只有精品|